SA2A2-502 [KYOCERA AVX]

Data Line Filter, 1 Function(s), 100V, 5A,;
SA2A2-502
型号: SA2A2-502
厂家: KYOCERA AVX    KYOCERA AVX
描述:

Data Line Filter, 1 Function(s), 100V, 5A,

LTE
文件: 总6页 (文件大小:83K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Bolt Style EMI Filters  
SA Series – 4-40 Thread - Epoxy Sealed –  
Circuits Available – C & L  
APPLICATIONS  
The SA series provides effective filtering  
in the RF and MICROWAVE frequency  
spectrums from 10 MHz through 26 GHz.  
Designed for mounting in a tapped  
bulkhead or with the standard nut and  
lockwasher provided, it is ideal for high  
impedance circuits where large capaci-  
tance values are not practical. In the L”  
section version an internal ferrite bead  
element provides both inductance and  
series resistance (lossy characteristic)  
which improves insertion loss and pro-  
vides superior transient performance. The  
SA series comes with a standard .020  
diameter beryllium copper lead. Alternate  
lead lengths, diameters of .016 or .026  
and alternate materials in steel or half-  
hard copper are available.  
CHARACTERISTICS  
• Meets or exceeds the applicable portions  
of MIL-F-28861/6. See QPL listings.  
• Features rugged monolithic discoidal  
capacitor construction.  
• Smallest screwbody filter available.  
• Epoxy seal on both ends.  
SPECIFICATIONS  
1. Plating: Silver standard – Electro-tin or  
gold available  
STANDARD CONFIGURATION  
A
.154  
.159  
.030  
MAX.  
.112-40 UNC-2A  
(4-40)  
2. Material:  
Case: Cold rolled steel  
.020 ±.002  
(Std. - See Note 1)  
Leads: Beryllium copper (steel or half/hard  
copper leads available)  
3. Operating Temperature Range:  
-55°C to +125°C  
.030  
MAX.  
A = .120 ±.005  
(See Note 2)  
.220  
±.010  
4. Insulation Resistance:  
At 25°C: 1,000 megohm-microfarad  
min., or 100,000 megohms  
min., whichever is less  
.240  
±.020  
.360  
±.020  
At 125°C: 100 megohm-microfarad  
min., or 10,000 megohms  
min., whichever is less  
CIRCUIT DIAGRAMS  
5. Dielectric Withstanding Voltage (DWV):  
R-level designs:  
THRD  
END  
L2  
C
2.0 times rated DC voltage  
SA1  
SA2 (See Note 3)  
Class B, Class S designs:  
2.5 times rated DC voltage  
6. DC Resistance (DCR): .02 ohm,  
maximum  
Notes:  
millimeters (inches)  
0.05 (.002) 3.05 (.120)  
0.13 (.005) 3.68 (.145)  
0.25 (.010) 3.91 (.154)  
0.41 (.016) 4.04 (.159)  
0.51 (.020) 5.59 (.220)  
0.66 (.026) 6.10 (.240)  
0.76 (.030) 9.14 (.360)  
1. Standard catalog designs  
have .020" dia. lead. MIL-F-  
28861/6 calls for .026" dia.  
.026" dia. will not be supplied  
unless specified.  
3. All SA2 L-Section Filters have  
inductor (bead) at threaded  
end.  
7. Dissipation Factor (DF): 3% maximum  
8. Rated DC Current: 5 Amps, maximum  
4. Metric equivalent dimensions  
given for information only.  
9. Recommended Mounting Torque:  
32 oz-in. ± 4 oz-in.  
2. “Adimension of .120 ± .005  
will satisfy M28861/6-003  
requirement for .145 ± .030.  
All “SAseries are supplied  
A = .120 ± .005.  
10. Supplied with mounting nut and lock-  
washer - See Filter Design Guide Screw  
and Locking Washer Table  
2.84 (.112)  
(See Note 4)  
11. Insertion Loss for the C” and L” sections  
are equivalent due to the saturation  
characteristic of the ferrite bead element  
at rated current. At lower currents the L”  
becomes much more effective.  
19  
Bolt Style EMI Filters  
SA Series – 4-40 Thread - Epoxy Sealed –  
Circuits Available – C & L  
SPECIFICATIONS  
Insertion Loss2 Per MIL-STD-220, +25°C  
AVX  
P/N  
DC  
Voltage  
1
10  
MHz  
100  
MHz  
200  
MHz  
1
GHz  
10  
GHz  
CKT  
C
CAP1  
1000  
5000  
.01  
DCR  
.02  
.02  
.02  
.02  
.02  
.02  
.02  
.02  
.02  
.02  
.02  
.02  
.02  
.02  
.02  
.02  
.02  
.02  
.02  
.02  
.02  
.02  
.02  
.02  
.02  
.02  
MHz  
SA1C1-102  
SA1C1-502  
SA1C1-103  
SA1C1-273  
SA1C1-503  
SA2C1-102  
SA2C1-502  
SA2C1-103  
SA2C1-273  
SA2C1-503  
SA1A1-102  
SA1A1-502  
SA1A1-103  
SA1A1-273  
SA1A1-453  
SA2A1-102  
SA2A1-502  
SA2A1-103  
SA2A1-273  
SA2A1-453  
SA1B1-102  
SA1B1-502  
SA1B1-103  
SA2B1-102  
SA2B1-502  
SA2B1-103  
50  
50  
4
20  
34  
35  
39  
42  
20  
35  
35  
50  
45  
20  
35  
35  
39  
42  
20  
35  
35  
50  
45  
20  
34  
35  
20  
35  
35  
25  
41  
42  
43  
45  
27  
41  
44  
45  
45  
25  
41  
42  
43  
45  
27  
41  
44  
45  
45  
25  
41  
42  
27  
41  
44  
25  
42  
50  
65  
70  
30  
45  
50  
65  
70  
25  
42  
50  
65  
70  
30  
45  
50  
70  
70  
25  
42  
50  
30  
45  
50  
55  
55  
70  
70  
70  
60  
60  
70  
70  
70  
55  
55  
70  
70  
70  
60  
60  
70  
70  
70  
55  
55  
70  
60  
60  
70  
C
15  
21  
30  
35  
4
C
50  
4
C
.027  
.05  
50  
10  
15  
C
50  
L2  
L2  
L2  
L2  
L2  
C
1000  
5000  
.01  
50  
50  
15  
21  
30  
37  
4
50  
4
.027  
.05  
50  
10  
15  
50  
1000  
5000  
.01  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
200  
200  
200  
200  
200  
200  
C
15  
21  
30  
35  
4
C
4
C
.027  
.045  
1000  
5000  
.01  
10  
14  
C
L2  
L2  
L2  
L2  
L2  
C
15  
21  
30  
37  
4
4
.027  
.045  
1000  
5000  
.01  
10  
14  
C
15  
21  
4
C
4
L2  
L2  
L2  
1000  
5000  
.01  
15  
21  
4
1
2
Decimal point values indicate capacitance in microfarads.  
Non-decimal point values indicate capacitance in picofarads.  
Insertion loss limits are based on theoretical values.  
Actual measurements may vary due to internal capacitor  
resonances and other design constraints.  
20  
Screw & Locking Washer Table  
HEX NUT AND INTERNAL TOOTH LOCKWASHER  
THREAD  
A
B
C
D
HEX NUT  
WASHER  
Size Thread  
Hex Nut  
Lockwasher  
A
B
C
D
4-40 UNC-2B  
(.112-40)  
.187*  
.180  
.257  
.241  
.067*  
.057  
.083  
.073  
.225*  
.215  
.265  
.255  
.020*  
.010  
.018  
.012  
(STD)  
(ALT)  
8-32 UNC-2B  
(.164-32)  
.250*  
.241  
.313  
.307  
.083*  
.073  
.114  
.104  
.285*  
.275  
.336  
.325  
.025*  
.015  
.025  
.015  
(STD)  
(ALT)  
10-32 UNF-2B  
(.190-32)  
.250  
.241  
.345  
.336  
.080  
.070  
.130  
.120  
.311  
.300  
.381  
.370  
.023  
.013  
.027  
.017  
(STD)  
(ALT)  
12-32 UNEF-2B  
(.216-32)  
.250  
.241  
.250*  
.241  
.083  
.073  
.073*  
.063  
.383  
.372  
.383*  
.372  
.023  
.013  
.023*  
.013  
(STD)  
(ALT)  
1/4-28 UNF-2B  
(.250-28)  
.311*  
.308  
.096*  
.091  
.408*  
.396  
.021*  
.015  
5/16-24 UNF-2B  
(.312-24)  
.377*  
.365  
.096*  
.091  
.435*  
.425  
.027*  
.017  
*Used for MIL-F-28861 units.  
Thread  
Recommended Mounting Torque  
(.112-40)  
4-40 UNC-2A  
32 oz-in. ± 4 oz-in.  
(.164-32)  
64 oz-in. ± 4 oz-in.  
64 oz-in. ± 4 oz-in.  
64 oz-in. ± 4 oz-in.  
44 oz-in. ± 4 oz-in.  
60 oz-in. ± 4 oz-in.  
8-32 UNC-2A  
(.190-32)  
10-32 UNC-2A  
(.216-32)  
12-32 UNEF-2A  
(.250-28)  
1/4-28 UNF-2A  
(.312-24)  
5/16-24 UNF-2A  
4
How To Order  
Notes  
NOTE 1:  
CAPACITANCE CODE  
All AVX Filters part numbers, with exception of certain cylin-  
drical styles, show total filter capacitance using the 3-digit  
EIA code. The first two digits are significant: the last digit is  
the multiplier.  
NOTE 4:  
VOLTAGE CODES AND FILTER  
VOLTAGE RATINGS  
IMPORTANT: please contact AVX Filters Applications  
Engineering when considering DC-rated filter designs for  
possible use in AC applications. As a general rule, DC  
designs may be derated for AC applications. Let us assist  
you.  
Example:  
103=10000 picofarads  
125=1200000 picofarads  
(1.2 microfarads)  
The voltage code letters must be selected consistent with  
the capabilities as outlined in the product selection tables for  
a given filter type. It is important to note that the same code  
letter may signify a different voltage rating depending upon  
filter type. For example: the L” code signifies a 200  
VDC/125 VAC rating for a bolt-style filter, but it describes a  
300 VDC/125 VAC design when applied to a JD-style filter.  
It is important to note that ¹ filters and multisection filters are  
described using the EIA code from the standpoint of total  
capacitance. Capacitance is understood to be specified  
as guaranteed minimum value” (GMV) unless otherwise  
specified. AVX Filters can supply ±20% or other specified  
tolerances at an additional charge. Contact AVX Filters  
Applications Engineering for further information.  
NOTE 5:  
NOTE 2:  
RELIABILITY CODES  
The customer must select the reliability code to be consis-  
tent with the filter application. As a minimum, all catalog  
filters are available as R-level designs.  
TERMINAL AND LEADWIRE CODES  
Non-standard terminal configurations including special  
materials or finishes are available. Please indicate a descrip-  
tion and/or outline drawing when requesting a non-standard  
terminal (code 3).  
Options:  
-” signifies an R-level filter design without the optional  
R-level high-rel screening  
NOTE 6:  
SPECIAL INFORMATION FOR  
CYLINDRICAL STYLE FILTERS  
“R” R-level design with optional R-level high-rel screening  
also specified  
L-section filter designs must be specified with regard to  
standard” or reverse” configuration. The L-section filter is  
normally utilized with the capacitor on the high impedance  
side of the circuit and the inductor looking into the low  
impedance side. Compact filter types such as the BK2  
or CK2 button filters with ferrite bead inductors are only  
supplied with the bead assembled into the threaded end.  
GK2 and JD2 L-section filters are normally supplied with  
a schematic or other marking to indicate location of the  
inductor.  
“B” Class B design with Group A screening per M28861 for  
Class B filters  
S” Class S design with Group A screening per M28861 for  
Class S (space grade) filters  
Please refer to the catalog section on Reliability for additional  
information on how to select reliability codes.  
NOTE 3:  
SPECIAL DESIGN CODE  
(ASSIGNED BY AVX FILTERS)  
A special suffix to the standard part number will be added by  
AVX Filters Applications Engineering to describe special  
designs or designs that are controlled by customer specifi-  
cations. It is important to note that even in those instances  
where a customer drawing describes a standard catalog  
design it is AVX Filters policy to assign a special part number  
to the customer drawing for configuration control.  
AC-rated catalog designs incorporate reduced values of  
capacitance to limit reactive current heating (and subsequent  
filter temperature rise) to safe levels. Do not specify a  
DC-rated filter with larger capacitance for an AC application  
without contacting AVX Filters Applications Engineering.  
51  
How To Order  
Part Number Construction  
SOLDER-IN STYLE  
Z
S
2
C
2
1
0
3
H
X
X
Glass Seal  
Orientation  
S - Standard  
R - Reverse  
Q - Hermetic  
(Glass Both  
Sides)  
N - No Glass  
(Epoxy Both  
Sides)  
Voltage  
A - 100 VDC  
B - 200 VDC  
C - 50 VDC  
E - 400 VDC/  
230 VAC  
F - 500 VDC  
G - 1000 VDC  
K - 250 VDC  
L - 300 VDC or  
200 VDC/  
Reliability  
Code  
See Notes  
Use H”  
to specify  
Hi-  
Temperature  
(300°C)  
Rated  
Design  
Y - Solder  
Basic Style  
Circuit  
0 - Non-Feed  
Thru Post  
1 - Feed Thru  
2 - L-Section  
3-Digit  
Capacitor  
Code  
Special  
Design  
(Customer  
DWG. or QPL  
Designation)  
Lead  
2 - Nickel Iron  
(Standard)  
3 - Special  
4 - Aluminum  
zz  
Z
Y
X
W
115 VAC  
M - 350 VDC  
N - 70 VDC  
(In pF)  
Compatible with  
seating flange  
(Std. Lead)  
5 - Aluminum  
Compatible with  
seating flange  
(Special Lead)  
D - Aluminum  
Compatible with  
centering flange  
(Std. Lead)  
E - Aluminum  
Compatible with  
Centering flange  
(Special Lead)  
F - Aluminum  
Compatible with  
Special Design  
BOLT STYLE  
SB  
2
A
1
1
0
3
X X  
Reliability  
Code  
(-See Note 2)  
Special Design  
(-See Note 3)  
Circuit  
1 - Feedthru (C)  
2 - L-Section (L)  
Voltage  
A - 100 VDC  
B - 200 VDC  
3 - PI-Section (¹) C - 50 VDC  
F - 500 VDC  
G - 1000 VDC  
H - 150 VDC  
J - 600 VDC  
K - 250 VDC  
L - 200 VDC/  
Basic Style  
SA-4-40  
SG-6-32  
SB-8-32  
SM-8-32  
SH-10-32 Epoxy Sealed  
SJ-12-28 Epoxy Sealed  
SC-12-32 Epoxy Sealed (.187 Hex)  
SP-12-32 Epoxy Sealed (.250 Hex)  
SN-12-32 Hermetic Sealed  
SL-1/4-28 Epoxy Sealed  
3-Digit Capacitor  
Code  
(-See Note 1)  
Terminal  
1 - Copper  
2 - Steel  
3 - Special Lead  
Design  
125 VAC  
M - 350 VDC  
N - 70 VDC  
Epoxy Sealed  
Epoxy Sealed  
Epoxy Sealed  
Hermetic Sealed  
4 - Beryllium  
Copper  
SD-5/16-24 Epoxy Sealed  
SF-5/16-32 Epoxy Sealed  
52  
How To Order  
Part Number Construction  
CYLINDRICAL STYLE  
G
K
2
A
A
S07  
XX  
Thread  
Length  
A - .187" (See Notes)  
B - .312"  
Reliability  
Code  
Special Design  
(Customer DWG.  
or QPL  
Basic Style  
A - Button Type  
(.410 Dia.)  
B - Button Type  
(.375 Dia.)  
Thread Type  
K - 1/4-28 Herm 0 - Feedthru Lead A - 100 VDC  
Seal  
L - 1/4-28 Epoxy  
Seal  
M - 8-32 Herm  
Seal  
N - 12-32 Herm  
Seal  
Circuit  
Voltage  
(without  
Capacitor)  
1 - Feedthru  
Capacitor  
2 - L-Section  
Filter  
B - 200 VDC  
C - 50 VDC  
E - 400 VDC/  
230 VAC  
F - 500 VDC  
G - 1000 VDC  
H - 150 VDC  
J - 600 VDC  
K - 250 VDC  
L - 200 VDC/  
125 VAC  
Designation)  
Feedthrus &  
BK2, CK2  
All Other  
Circuit Types  
C - Extended  
Button  
G - .375" Dia.  
J - .690" Dia.  
H - .410" Dia.  
F - .250" Dia.  
Q - Special  
X X X  
Capacitance In  
Picofarads  
3 - PI Filter  
4 - T-Section  
T - 1/4-28  
Post Terminal 5 - Double  
(Both Ends)  
V - 1/4-28 Post 6 - Five Element  
and Flag  
Terminal  
X - 1/4-28 Hex  
Adaptor  
Current Rating  
L-Section  
Circuit  
Code  
Current  
S - Standard L  
(Inductor at  
Thread End)  
R - Reverse L  
(Capacitor at  
Thread End)  
P - PI-Circuit  
M - Multi  
01  
02  
03  
04  
05  
06  
07  
08  
09  
10  
11  
12  
16  
17  
18  
19  
.06 AMP  
.1  
Cap Input  
7 - Five Element  
IND Input  
8 - Special Ckt.  
Design  
(Except JD  
Series  
300 VDC/  
.15  
.25  
.3  
.45  
.5  
1
2
3
5
10  
4
6
.75  
1.5  
125 VAC)  
M - 350 VDC  
N - 70 VDC  
Section  
T - T Circuit  
Please contact the factory for Filter Plates  
and other custom product part numbers.  
NOTICE: Specifications are subject to change without notice. Contact your nearest AVX Sales Office for the latest specifications. All statements, information and  
data given herein are believed to be accurate and reliable, but are presented without guarantee, warranty, or responsibility of any kind, expressed or implied.  
Statements or suggestions concerning possible use of our products are made without representation or warranty that any such use is free of patent infringement  
and are not recommendations to infringe any patent. The user should not assume that all safety measures are indicated or that other measures may not be  
required. Specifications are typical and may not apply to all applications.  
53  

相关型号:

SA2A2B050

Data Line Filter, 1 Function(s), 100V, 5A,
KYOCERA AVX

SA2A2B123

Data Line Filter, 1 Function(s), 100V, 5A,
KYOCERA AVX

SA2A2R102

Data Line Filter, 1 Function(s), 100V, 5A,
KYOCERA AVX

SA2A2R103

Data Line Filter, 1 Function(s), 100V, 5A,
KYOCERA AVX

SA2A2R273

Data Line Filter, 1 Function(s), 100V, 5A,
KYOCERA AVX

SA2A2R453

Data Line Filter, 1 Function(s), 100V, 5A,
KYOCERA AVX

SA2A2R502

Data Line Filter, 1 Function(s), 100V, 5A,
KYOCERA AVX

SA2A2S050

Data Line Filter, 1 Function(s), 100V, 5A,
KYOCERA AVX

SA2A2S123

Data Line Filter, 1 Function(s), 100V, 5A,
KYOCERA AVX

SA2A3B050

Data Line Filter, 1 Function(s), 100V, 5A,
KYOCERA AVX

SA2A3B123

Data Line Filter, 1 Function(s), 100V, 5A,
KYOCERA AVX

SA2A3S050

Data Line Filter, 1 Function(s), 100V, 5A,
KYOCERA AVX